Updated 20 November 2026
Rational Method calculator (QUDM form) with worked examples
The Rational Method estimates the peak flow from a small catchment. Queensland practice uses the form in the Queensland Urban Drainage Manual (QUDM, published by IPWEA Queensland, ipweaq.com/qudm):
Q = Cy × I × A / 360, where Cy = Fy × C10 (not more than 1.0)
| Symbol | Meaning | Units |
|---|---|---|
| Q | peak flow for the design event | m³/s |
| C10 | 10-year (10% AEP) runoff coefficient | – |
| Fy | frequency factor for the design event | – |
| Cy | runoff coefficient for the design event, capped at 1.0 | – |
| I | average rainfall intensity for a storm duration equal to the time of concentration (tc) | mm/h |
| A | catchment area | ha |
The 360 converts mm/h × ha into m³/s. A runoff coefficient is the fraction of rainfall that becomes runoff, so Cy can't exceed 1.0. If Fy × C10 comes out above 1.0, use 1.0.
Where the inputs come from:
- C10 and Fy: the QUDM tables, or your local council's guideline if it varies them. Some councils do. Sunshine Coast Council's guideline, for example, sets its own C10 relationship and replaces the QUDM frequency factors (Sunshine Coast Council guideline).
- I: the Bureau of Meteorology design rainfall (IFD) data for your site (BoM design rainfalls), at your design AEP and a duration equal to tc, following Australian Rainfall and Runoff (ARR).
This page doesn't reproduce the QUDM tables. Use the current edition named in your project or council requirements.
Rational Method peak flow calculator (QUDM form)
Cy = Fy·C10:
Q = m³/s ( L/s)
Inputs shown are our test-case values, not design values. Take C10 and Fy from QUDM or your council guideline and I from BoM IFD data. Calculation aid only, not certified engineering advice.
Worked examples
The inputs below only illustrate the arithmetic. They aren't design values for any site.
Example 1: the spreadsheet's test case. C10 = 0.8, Fy = 1.0, I = 100 mm/h, A = 2.0 ha
- Cy = 1.0 × 0.8 = 0.80
- Q = 0.80 × 100 × 2.0 / 360 = 0.444 m³/s (444 L/s)
Example 2: the 1.0 cap applies. C10 = 0.9, Fy = 1.2, I = 150 mm/h, A = 0.5 ha
- Fy × C10 = 1.08, so Cy = 1.0 (capped)
- Q = 1.0 × 150 × 0.5 / 360 = 0.208 m³/s (208 L/s)
- Without the cap you'd get 0.225 m³/s, an 8% overestimate.
Common slips
- Area in m² or km². The 360 only works with hectares. 20,000 m² is 2.0 ha.
- Wrong storm duration. I must be for a duration equal to the time of concentration of the catchment (or sub-catchment) you're checking, not a default such as 1 hour.
- Forgetting the cap. For rare events on highly impervious catchments, Fy × C10 often passes 1.0.
- AEP mismatch. Fy and I must both be for the same design event.
- Outside its range. The Rational Method suits small urban catchments. Check QUDM and your council's guidance on where it applies and when a runoff-routing model is needed.
Take it offline
The AU Civil Calculator Pack (A$29) has this Rational Method sheet with the 1.0 cap built in. It also has Manning full-pipe capacity, stopping sight distance, traffic control taper and sign spacing, pavement design traffic and quantities, with 8 hand-checked test cases. It comes in Excel and Google Sheets.
Want to start free? AU Civil Quick Calcs (A$0+) covers stopping sight distance plus concrete and asphalt quantities.
Calculation aid only. Templates only, not certified engineering advice. Check results against the current QUDM, ARR and your council's requirements, and have drainage design reviewed by a suitably qualified engineer (e.g. RPEQ) where required. Not endorsed by IPWEA Queensland or the Bureau of Meteorology.
Free download
Grab AU Civil Quick Calcs free (A$0+) on our store. It's the quickest way to try our templates.
Get the free calculatorsSources
- IPWEA Queensland, Queensland Urban Drainage Manual: https://www.ipweaq.com/qudm
- Bureau of Meteorology, design rainfall data system (IFD): https://www.bom.gov.au/water/designRainfalls/revised-ifd/
- Geoscience Australia, Australian Rainfall and Runoff: http://arr.ga.gov.au/
- Sunshine Coast Council, example of a local variation to QUDM C10 and frequency factors (see the link above)