JALS Engineering Templates

Updated 20 November 2026

Rational Method calculator (QUDM form) with worked examples

The Rational Method estimates the peak flow from a small catchment. Queensland practice uses the form in the Queensland Urban Drainage Manual (QUDM, published by IPWEA Queensland, ipweaq.com/qudm):

Q = Cy × I × A / 360, where Cy = Fy × C10 (not more than 1.0)

Symbol Meaning Units
Q peak flow for the design event m³/s
C10 10-year (10% AEP) runoff coefficient –
Fy frequency factor for the design event –
Cy runoff coefficient for the design event, capped at 1.0 –
I average rainfall intensity for a storm duration equal to the time of concentration (tc) mm/h
A catchment area ha

The 360 converts mm/h × ha into m³/s. A runoff coefficient is the fraction of rainfall that becomes runoff, so Cy can't exceed 1.0. If Fy × C10 comes out above 1.0, use 1.0.

Where the inputs come from:

This page doesn't reproduce the QUDM tables. Use the current edition named in your project or council requirements.

Rational Method peak flow calculator (QUDM form)

Cy = Fy·C10:
Q = m³/s ( L/s)

Inputs shown are our test-case values, not design values. Take C10 and Fy from QUDM or your council guideline and I from BoM IFD data. Calculation aid only, not certified engineering advice.

Worked examples

The inputs below only illustrate the arithmetic. They aren't design values for any site.

Example 1: the spreadsheet's test case. C10 = 0.8, Fy = 1.0, I = 100 mm/h, A = 2.0 ha

Example 2: the 1.0 cap applies. C10 = 0.9, Fy = 1.2, I = 150 mm/h, A = 0.5 ha

Common slips

Take it offline

The AU Civil Calculator Pack (A$29) has this Rational Method sheet with the 1.0 cap built in. It also has Manning full-pipe capacity, stopping sight distance, traffic control taper and sign spacing, pavement design traffic and quantities, with 8 hand-checked test cases. It comes in Excel and Google Sheets.

Want to start free? AU Civil Quick Calcs (A$0+) covers stopping sight distance plus concrete and asphalt quantities.

Calculation aid only. Templates only, not certified engineering advice. Check results against the current QUDM, ARR and your council's requirements, and have drainage design reviewed by a suitably qualified engineer (e.g. RPEQ) where required. Not endorsed by IPWEA Queensland or the Bureau of Meteorology.

Sources